Nickel & Its Uses
print this page make fonts smallermake fonts bigger

Technical Literature Locator

Browse
Microbiological Influence (10085)
By G. Kobrin et al., originally presented at the 58th Annual International Water Conference, November 3-5, 1997, Pittsburgh, PA. Case histories from experience and the published literature illustrate factors which resulted in microbiologically influenced corrosion (MIC) of stainless steel piping, storage tanks and heat exchangers by waters used for hydrotesting, cooling and other purposes. Practices which will prevent or reduce potential for MIC, including material substitution, are discussed, along with efforts to heighten awareness of the problem.